make example config same as standard config
This commit is contained in:
parent
1acc57733c
commit
273ef866cc
@ -1,5 +1,7 @@
|
|||||||
import logging
|
import logging
|
||||||
from lib.max31856 import MAX31856
|
|
||||||
|
# uncomment this if using MAX-31856
|
||||||
|
#from lib.max31856 import MAX31856
|
||||||
|
|
||||||
########################################################################
|
########################################################################
|
||||||
#
|
#
|
||||||
@ -35,7 +37,8 @@ gpio_heat = 23 # Switches zero-cross solid-state-relay
|
|||||||
max31855 = 1
|
max31855 = 1
|
||||||
max31856 = 0
|
max31856 = 0
|
||||||
# see lib/max31856.py for other thermocouple_type, only applies to max31856
|
# see lib/max31856.py for other thermocouple_type, only applies to max31856
|
||||||
thermocouple_type = MAX31856.MAX31856_S_TYPE
|
# uncomment this if using MAX-31856
|
||||||
|
#thermocouple_type = MAX31856.MAX31856_S_TYPE
|
||||||
|
|
||||||
### Thermocouple Connection (using bitbang interfaces)
|
### Thermocouple Connection (using bitbang interfaces)
|
||||||
gpio_sensor_cs = 27
|
gpio_sensor_cs = 27
|
||||||
@ -61,16 +64,10 @@ sensor_time_wait = 2
|
|||||||
# well with the simulated oven. You must tune them to work well with
|
# well with the simulated oven. You must tune them to work well with
|
||||||
# your specific kiln. Note that the integral pid_ki is
|
# your specific kiln. Note that the integral pid_ki is
|
||||||
# inverted so that a smaller number means more integral action.
|
# inverted so that a smaller number means more integral action.
|
||||||
|
pid_kp = 25 # Proportional
|
||||||
|
pid_ki = 200 # Integral
|
||||||
|
pid_kd = 200 # Derivative
|
||||||
|
|
||||||
# from experimentation
|
|
||||||
#pid_kp = 10 # Proportional
|
|
||||||
#pid_ki = 50 # Integral
|
|
||||||
#pid_kd = 100 # Derivative
|
|
||||||
|
|
||||||
# from ZN tuning
|
|
||||||
pid_kp = 3.0662264423638184
|
|
||||||
pid_ki = 61.295706065671204
|
|
||||||
pid_kd = 144.07164331295013
|
|
||||||
|
|
||||||
########################################################################
|
########################################################################
|
||||||
#
|
#
|
||||||
@ -86,12 +83,12 @@ stop_integral_windup = True
|
|||||||
########################################################################
|
########################################################################
|
||||||
#
|
#
|
||||||
# Simulation parameters
|
# Simulation parameters
|
||||||
simulate = False
|
simulate = True
|
||||||
sim_t_env = 60.0 # deg C
|
sim_t_env = 60.0 # deg C
|
||||||
sim_c_heat = 100.0 # J/K heat capacity of heat element
|
sim_c_heat = 100.0 # J/K heat capacity of heat element
|
||||||
sim_c_oven = 5000.0 # J/K heat capacity of oven
|
sim_c_oven = 5000.0 # J/K heat capacity of oven
|
||||||
sim_p_heat = 5450.0 # W heating power of oven
|
sim_p_heat = 5450.0 # W heating power of oven
|
||||||
sim_R_o_nocool = 1.0 # K/W thermal resistance oven -> environment
|
sim_R_o_nocool = 0.1 # K/W thermal resistance oven -> environment
|
||||||
sim_R_o_cool = 0.05 # K/W " with cooling
|
sim_R_o_cool = 0.05 # K/W " with cooling
|
||||||
sim_R_ho_noair = 0.1 # K/W thermal resistance heat element -> oven
|
sim_R_ho_noair = 0.1 # K/W thermal resistance heat element -> oven
|
||||||
sim_R_ho_air = 0.05 # K/W " with internal air circulation
|
sim_R_ho_air = 0.05 # K/W " with internal air circulation
|
||||||
@ -121,7 +118,7 @@ emergency_shutoff_temp = 2264 #cone 7
|
|||||||
# wanted temperature, the schedule will run forever. This is often used
|
# wanted temperature, the schedule will run forever. This is often used
|
||||||
# for heating as fast as possible in a section of a kiln schedule/profile.
|
# for heating as fast as possible in a section of a kiln schedule/profile.
|
||||||
kiln_must_catch_up = True
|
kiln_must_catch_up = True
|
||||||
kiln_must_catch_up_max_error = 10 #degrees
|
kiln_must_catch_up_max_error = 5 #degrees
|
||||||
|
|
||||||
# thermocouple offset
|
# thermocouple offset
|
||||||
# If you put your thermocouple in ice water and it reads 36F, you can
|
# If you put your thermocouple in ice water and it reads 36F, you can
|
||||||
@ -143,3 +140,11 @@ temperature_average_samples = 40
|
|||||||
|
|
||||||
# Thermocouple AC frequency filtering - set to True if in a 50Hz locale, else leave at False for 60Hz locale
|
# Thermocouple AC frequency filtering - set to True if in a 50Hz locale, else leave at False for 60Hz locale
|
||||||
ac_freq_50hz = False
|
ac_freq_50hz = False
|
||||||
|
|
||||||
|
# There are all kinds of emergencies that can happen including:
|
||||||
|
# - temperature is too high (emergency_shutoff_temp exceeded)
|
||||||
|
# - lost connection to thermocouple
|
||||||
|
# - unknown error with thermocouple
|
||||||
|
# - too many errors in a short period from thermocouple
|
||||||
|
# and some people just want to ignore all of that and just log the emergencies but do not quit
|
||||||
|
ignore_emergencies = False
|
||||||
|
|||||||
Loading…