diff --git a/config.py b/config.py index 039de3e..456f716 100644 --- a/config.py +++ b/config.py @@ -80,6 +80,12 @@ temp_scale = "f" # c = Celsius | f = Fahrenheit - Unit to display time_scale_slope = "h" # s = Seconds | m = Minutes | h = Hours - Slope displayed in temp_scale per time_scale_slope time_scale_profile = "m" # s = Seconds | m = Minutes | h = Hours - Enter and view target time in time_scale_profile +# emergency shutoff the kiln if this temp is reached. +# when solid state relays fail, they usually fail closed. this means your +# kiln receives full power until your house burns down. +# this should not replace you watching your kiln or use of a kiln-sitter +emergency_shutoff_temp = 2250 + # not used yet # if measured value is N degrees below set point warning_temp_low = 5 @@ -88,8 +94,9 @@ warning_temp_low = 5 # if measured value is N degrees above set point warning_temp_high = 5 -# emergency shutoff the kiln if this temp is reached. -# when solid state relays fail, they usually fail closed. this means your -# kiln receives full power until your house burns down. -# this should not replace you watching your kiln or use of a kiln-sitter -emergency_shutoff_temp = 2250 +# not used yet +# thermocouple offset +# If you put your thermocouple in ice water and it reads 36F, you can +# set set this offset to -4 to compensate. This probably means you have a +# cheap thermocouple. Invest in a better thermocouple. +thermocouple_offset=0 diff --git a/config.py.EXAMPLE b/config.py.EXAMPLE index f8fe225..456f716 100644 --- a/config.py.EXAMPLE +++ b/config.py.EXAMPLE @@ -80,3 +80,23 @@ temp_scale = "f" # c = Celsius | f = Fahrenheit - Unit to display time_scale_slope = "h" # s = Seconds | m = Minutes | h = Hours - Slope displayed in temp_scale per time_scale_slope time_scale_profile = "m" # s = Seconds | m = Minutes | h = Hours - Enter and view target time in time_scale_profile +# emergency shutoff the kiln if this temp is reached. +# when solid state relays fail, they usually fail closed. this means your +# kiln receives full power until your house burns down. +# this should not replace you watching your kiln or use of a kiln-sitter +emergency_shutoff_temp = 2250 + +# not used yet +# if measured value is N degrees below set point +warning_temp_low = 5 + +# not used yet +# if measured value is N degrees above set point +warning_temp_high = 5 + +# not used yet +# thermocouple offset +# If you put your thermocouple in ice water and it reads 36F, you can +# set set this offset to -4 to compensate. This probably means you have a +# cheap thermocouple. Invest in a better thermocouple. +thermocouple_offset=0