calculate bad percent in temperature thread to prevent threading/boundary issues
This commit is contained in:
parent
c955c1f595
commit
610ad4cdcd
@ -100,6 +100,7 @@ class TempSensorReal(TempSensor):
|
|||||||
self.bad_count = 0
|
self.bad_count = 0
|
||||||
self.ok_count = 0
|
self.ok_count = 0
|
||||||
self.bad_stamp = 0
|
self.bad_stamp = 0
|
||||||
|
self.bad_percent = 0
|
||||||
|
|
||||||
if config.max31855:
|
if config.max31855:
|
||||||
log.info("init MAX31855")
|
log.info("init MAX31855")
|
||||||
@ -126,7 +127,8 @@ class TempSensorReal(TempSensor):
|
|||||||
temps = []
|
temps = []
|
||||||
while True:
|
while True:
|
||||||
# reset error counter if time is up
|
# reset error counter if time is up
|
||||||
if (time.time() - self.bad_stamp) > (self.time_step * 4):
|
if (time.time() - self.bad_stamp) > (self.time_step * 2):
|
||||||
|
self.bad_percent = (self.bad_count / (self.bad_count + self.ok_count)) * 100
|
||||||
self.bad_count = 0
|
self.bad_count = 0
|
||||||
self.ok_count = 0
|
self.ok_count = 0
|
||||||
self.bad_stamp = time.time()
|
self.bad_stamp = time.time()
|
||||||
@ -244,7 +246,7 @@ class Oven(threading.Thread):
|
|||||||
log.info("emergency!!! unknown thermocouple error, shutting down")
|
log.info("emergency!!! unknown thermocouple error, shutting down")
|
||||||
self.reset()
|
self.reset()
|
||||||
|
|
||||||
if self.board.temp_sensor.bad_count / (self.board.temp_sensor.bad_count + self.board.temp_sensor.ok_count) > 0.3:
|
if self.board.temp_sensor.bad_percent > 30:
|
||||||
log.info("emergency!!! too many errors in a short period, shutting down")
|
log.info("emergency!!! too many errors in a short period, shutting down")
|
||||||
self.reset()
|
self.reset()
|
||||||
|
|
||||||
|
|||||||