cleaning up config given latest code changes
This commit is contained in:
parent
bcfd6afbc7
commit
7d68878fbb
29
config.py
29
config.py
@ -43,10 +43,13 @@ gpio_sensor_clock = 22
|
||||
gpio_sensor_data = 17
|
||||
gpio_sensor_di = 10 # only used with max31856
|
||||
|
||||
### duty cycle of the entire system in seconds. Every N seconds a decision
|
||||
### is made about switching the relay[s] on & off and for how long.
|
||||
### The thermocouple is read five times during this period and the highest
|
||||
### value is used.
|
||||
########################################################################
|
||||
#
|
||||
# duty cycle of the entire system in seconds
|
||||
#
|
||||
# Every N seconds a decision is made about switching the relay[s]
|
||||
# on & off and for how long. The thermocouple is read
|
||||
# temperature_average_samples times during and the average value is used.
|
||||
sensor_time_wait = 2
|
||||
|
||||
|
||||
@ -54,8 +57,9 @@ sensor_time_wait = 2
|
||||
#
|
||||
# PID parameters
|
||||
#
|
||||
# These parameters work well with the simulated oven. You must tune them
|
||||
# to work well with your specific kiln. Note that the integral pid_ki is
|
||||
# These parameters control kiln temperature change. These settings work
|
||||
# well with the simulated oven. You must tune them to work well with
|
||||
# your specific kiln. Note that the integral pid_ki is
|
||||
# inverted so that a smaller number means more integral action.
|
||||
pid_kp = 25 # Proportional
|
||||
pid_ki = 200 # Integral
|
||||
@ -108,7 +112,8 @@ emergency_shutoff_temp = 2264 #cone 7
|
||||
# If the kiln cannot heat or cool fast enough and is off by more than
|
||||
# kiln_must_catch_up_max_error the entire schedule is shifted until
|
||||
# the desired temperature is reached. If your kiln cannot attain the
|
||||
# wanted temperature, the schedule will run forever.
|
||||
# wanted temperature, the schedule will run forever. This is often used
|
||||
# for heating as fast as possible in a section of a kiln schedule/profile.
|
||||
kiln_must_catch_up = True
|
||||
kiln_must_catch_up_max_error = 10 #degrees
|
||||
|
||||
@ -118,13 +123,15 @@ kiln_must_catch_up_max_error = 10 #degrees
|
||||
# cheap thermocouple. Invest in a better thermocouple.
|
||||
thermocouple_offset=0
|
||||
|
||||
# some kilns/thermocouples start erroneously reporting "short" errors at higher temperatures
|
||||
# due to plasma forming in the kiln.
|
||||
# Set this to False to ignore these errors and assume the temperature reading was correct anyway
|
||||
# some kilns/thermocouples start erroneously reporting "short"
|
||||
# errors at higher temperatures due to plasma forming in the kiln.
|
||||
# Set this to False to ignore these errors and assume the temperature
|
||||
# reading was correct anyway
|
||||
honour_theromocouple_short_errors = False
|
||||
|
||||
# number of samples of temperature to average.
|
||||
# If you suffer from the high temperature kiln issue and have set honour_theromocouple_short_errors to False,
|
||||
# If you suffer from the high temperature kiln issue and have set
|
||||
# honour_theromocouple_short_errors to False,
|
||||
# you will likely need to increase this (eg I use 40)
|
||||
temperature_average_samples = 40
|
||||
|
||||
|
||||