--- tag: g090 title: Absolute Positioning brief: Set the interpreter to absolute positions author: thinkyhead since: 1.0.0-beta group: units codes: [ G90 ] notes: - Absolute positioning is the default. example: - pre: Enable absolute mode code: - G90 ; Set all axes to absolute --- In absolute mode all coordinates given in G-code are interpreted as positions in the logical coordinate space. This includes the extruder position unless overridden by [`M83`](/docs/gcode/M083.html).