--- tag: m0302 title: Cold Extrude brief: Set minimum extrusion temperature, allow cold extrusion. author: thinkyhead requires: PREVENT_COLD_EXTRUSION group: thermal codes: [ M302 ] notes: Requires `PREVENT_COLD_EXTRUSION`. parameters: - tag: S optional: true description: Minimum temperature for safe extrusion values: - tag: temp type: float - tag: P optional: true description: Flag to allow extrusion at any temperature values: - tag: flag type: bool examples: - pre: Some common uses... code: | M302 ; report current cold extrusion state M302 P0 ; enable cold extrusion checking M302 P1 ; disable cold extrusion checking M302 S0 ; always allow extrusion (disable checking) M302 S170 ; only allow extrusion above 170 M302 S170 P1 ; set min extrude temp to 170 but leave disabled --- Set the minimum extrusion temperature, potentially allowing E movement at temperatures below the melting point of the material.