--- tag: m0104 title: Set Hotend Temperature brief: Set a new target hot end temperature. author: thinkyhead group: thermal codes: [ M104 ] notes: | - With `PRINTJOB_TIMER_AUTOSTART` this command will stop the print job timer if the temperature is set at or below half of `EXTRUDE_MINTEMP`. parameters: - tag: I since: 2.0.6 optional: true description: Material preset index. Overrides `S`. values: - type: int tag: index - tag: S optional: true description: 'Target temperature.
`AUTOTEMP`: the min auto-temperature.' values: - tag: temp type: float - tag: F optional: true description: '`AUTOTEMP`: Autotemp flag. Omit to disable autotemp.' values: - tag: flag type: bool - tag: B optional: true description: '`AUTOTEMP`: The max auto-temperature.' values: - tag: temp type: float - tag: T optional: true description: Hotend index. If omitted, the currently active hotend will be used. values: - tag: index type: int examples: - pre: Set target temperature for the active hotend code: M104 S185 - pre: Set target temperature for E1 code: M104 T1 S205 - pre: '`AUTOTEMP`: Set autotemp range' code: M104 F S180 B190 - pre: '`AUTOTEMP`: Disable autotemp' code: M104 --- Set a new target hot end temperature and continue without waiting. The firmware will continue to try to reach and hold the temperature in the background. Use [`M109`](/docs/gcode/M109.html) to wait for the hot end to reach the target temperature.