#ifndef OMRON_E5_H
#define OMRON_E5_H
#include "config.h"
#ifdef ENABLE_RS485
#include <ArduinoLog.h>
#include <Component.h>
#include <modbus/ModbusRTU.h>
#include <modbus/ModbusTypes.h>
#include "components/OmronE5Types.h"
#include <xstatistics.h>
#include "../ValueWrapper.h"
// #define ENABLE_TRUTH_COLLECTOR
#ifdef ENABLE_TRUTH_COLLECTOR
#include <xstatistics.h>
#endif
#define OMRON_E5_READ_BLOCK_START_ADDR 0x0000
#define OMRON_E5_READ_BLOCK_REG_COUNT 6
#define OMRON_E5_READ_BLOCK_INTERVAL 300
enum class E_ExecuteCommands : short {
INFO = 1,
RESET_STATS = 2
};
enum class E_OmronTcpOffset : ushort {
PV = 1,
STATUS_HIGH = 2,
STATUS_LOW = 3,
#ifdef ENABLE_TRUTH_COLLECTOR
MEAN_ERROR = 4,
SP = 5,
HEAT_RATE = 6,
WH_LOW = 7,
WH_HIGH = 8,
PV_SP_LAG = 9, // Tenths of PV Unit per minute (PV SP Lag)
TOTAL_COST_CENTS = 10, // Estimated total cost in Euro Cents
LONGEST_HEAT_60S = 15, // Longest heating duration in last 60s (seconds)
#else
SP = 5,
#endif
CMD_SP = 11,
CMD_STOP = 12,
CMD_EXECUTE = 13, // Write 1 for info, 2 for reset stats
IS_HEATING = 14, // Read-only status: 1 if heating, 0 otherwise
IS_HEATUP = 16, // Read-only status: 1 if PV < SP - Deadband
CMD_EXECUTE_INFO = 17
};
class OmronE5 : public RTU_Base
{
public:
// Calculate the number of TCP blocks based on conditional compilation
#ifdef ENABLE_TRUTH_COLLECTOR
static constexpr int OMRON_TCP_BLOCK_COUNT = 16;
#else
#ifdef ENABLE_COOLING // Added check for cooling when truth collector is off
static constexpr int OMRON_TCP_BLOCK_COUNT = 8; // Basic + CMDs + Heatup + CoolingMV
#else
static constexpr int OMRON_TCP_BLOCK_COUNT = 7; // Basic + CMDs + Heatup
#endif
#endif
// Constructor
OmronE5(Component* owner, uint8_t slaveId, millis_t readInterval = OMRON_E5_READ_BLOCK_INTERVAL);
virtual ~OmronE5() = default;
// --- Component Interface ---
virtual short setup() override;
virtual short loop() override;
virtual short info() override;
// --- Modbus Register Update Notification ---
virtual void onRegisterUpdate(uint16_t address, uint16_t newValue) override; // Override base method
// --- Getters for Specific Values ---
bool getPV(uint16_t& value) const;
bool getSP(uint16_t& value) const;
bool getStatusLow(uint16_t& value) const;
bool getStatusHigh(uint16_t& value) const;
bool isRunning() const;
bool isHeating() const;
bool isCooling() const;
bool isAutoTuning() const;
bool isHeatup() const;
#ifdef ENABLE_TRUTH_COLLECTOR
float getMeanError() const;
float getHeatRate() const;
float getTotalWh() const;
uint16_t getLongestHeatDuration60s() const; // Getter returns seconds
#endif
// --- Setters (Optional - Implement if needed) ---
bool setSP(uint16_t value);
bool run();
bool stop();
uint32_t getConsumption() const;
#ifdef ENABLE_COOLING
// --- Cooling Specific Getters ---
// Requires ENABLE_COOLING define in OmronE5.cpp and manual Omron device setup for cooling.
/**
* @brief Gets the raw 32-bit value of the Cooling Manipulated Variable (MV) monitor.
* Requires reading registers 0x2005 (Low) and 0x2006 (High).
* @param value Reference to store the combined 32-bit value.
* @return True if the value is valid (has been successfully read), false otherwise.
*/
bool getCoolingMVRaw(uint32_t& value) const;
// --- Cooling State (Requires ENABLE_COOLING in .cpp & manual device setup) ---
uint16_t _currentCoolingMVLow = 0;
uint16_t _currentCoolingMVHigh = 0;
bool _coolingMvValid = false;
#endif
// --- Modbus Block Definitions ---
virtual ModbusBlockView* mb_tcp_blocks() const override;
virtual short mb_tcp_read(MB_Registers * reg) override;
virtual short mb_tcp_write(MB_Registers * reg, short value) override;
// --- Modbus TCP Mapping Overrides ---
/**
* @brief Gets the base Modbus TCP address allocated for this RTU device instance.
* @return The base TCP address for this device instance.
*/
uint16_t mb_tcp_base_address() const override;
/**
* @brief Calculates the Modbus TCP offset corresponding to a given RTU address update.
* @param rtuAddress The RTU register address that was updated.
* @return The corresponding TCP offset (relative to mb_tcp_base_address), or 0 if no direct mapping exists for broadcast.
*/
uint16_t mb_tcp_offset_for_rtu_address(uint16_t rtuAddress) const override;
private:
millis_t _readInterval;
// --- Local State Storage ---
uint16_t _currentPV = 0;
uint16_t _currentSP = 0;
uint16_t _currentStatusLow = 0;
uint16_t _currentStatusHigh = 0;
bool _pvValid = false;
bool _spValid = false;
bool _statusValid = false; // Combined flag for low/high status pair
uint32_t _consumption = 2700; // Added consumption member (Watts) with default value
ValueWrapper<bool> _runStateWrapper; // Wrapper for Run/Stop state
#ifdef ENABLE_TRUTH_COLLECTOR
Statistic _errorStats;
Statistic _heatingIntervalStats;
bool _wasHeating = false;
millis_t _heatOnStartTime = 0;
float _totalWh = 0.0f;
// PV Rate of Change Calculation (PV SP Lag)
uint16_t _previousPV = 0;
millis_t _lastPvUpdateTime = 0;
int16_t _pvSpLag = 0; // Tenths of PV Unit per Minute (PV SP Lag)
bool _hasPreviousPv = false;
millis_t _lastHeatingLoopTime = 0; // Timestamp for continuous Wh calculation
// Longest Heating Duration Tracking (60s window)
millis_t _currentHeatStartTime = 0; // Start time of the current continuous heating period
millis_t _windowStartTime = 0; // Start time of the 60-second tracking window
uint16_t _maxHeatDurationInWindowSecs = 0; // Longest duration (seconds) found in the current window
/**
* @brief Resets all runtime statistics and timestamps used by the truth collector.
* Triggered by writing 2 to the CMD_EXECUTE register.
*/
void _resetRuntimeStats();
#endif
// NOTE: Size updated to match OMRON_TCP_BLOCK_COUNT
MB_Registers _modbusBlocks[OMRON_TCP_BLOCK_COUNT];
ModbusBlockView _modbusBlockView;
};
#endif // ENABLE_RS485
#endif // OMRON_E5_H