freecad-cam/Mod/cam-dev/ref-i530/a_phv3/brackets/probe-40.h
2026-02-01 19:47:58 +01:00

44 lines
1.2 KiB
C

0 BEGIN PGM probe-40 MM
1 BLK FORM 0.1 Z X-56.209 Y-90 Z-30
2 BLK FORM 0.2 X+56.209 Y+49.75 Z+0
3 ;-------------------------------------
4 ;Tools
5 ; #100 D=6 CR=3 - ZMIN=-6 - ZMAX=+55 - probe
6 ; Heidenhain
7 ;-------------------------------------
8 ;
9 * - Probe WCS6
10 M5
11 TOOL CALL 100 Z S50
12 L M140 MB MAX
13 L X+0 Y+0 R0 FMAX
14 L Z+55 R0 FMAX
15 CYCL DEF 32.0 TOLERANCE
16 CYCL DEF 32.1
17 TCH PROBE 412 DATUM INSIDE CIRCLE ~
Q321=+0 ;CENTER IN 1ST AXIS ~
Q322=+0 ;CENTER IN 2ND AXIS ~
Q262=+40 ;NOMINAL DIAMETER ~
Q325=+0 ;STARTING ANGLE ~
Q247=+90 ;STEPPING ANGLE ~
Q261=-3 ;MEASURING HEIGHT ~
Q320=+12 ;SET-UP CLEARANCE ~
Q260=+5 ;CLEARANCE HEIGHT ~
Q301=+0 ;MOVE TO CLEARANCE ~
Q305=+0 ;NUMBER IN TABLE ~
Q331=+0 ;DATUM ~
Q332=+0 ;DATUM ~
Q303=+1 ;MEAS. VALUE TRANSFER ~
Q381=+0 ;PROBE IN TS AXIS ~
Q382=+0 ;1ST CO. FOR TS AXIS ~
Q383=+0 ;2ND CO. FOR TS AXIS ~
Q384=+0 ;3RD CO. FOR TS AXIS ~
Q333=+0 ;DATUM ~
Q423=+4 ;NO. OF MEAS. POINTS ~
Q365=+1 ;TYPE OF TRAVERSE
18 L Z+55 FMAX
19 M5
20 L M140 MB MAX
21 M30
22 END PGM probe-40 MM