Device,Register (3),Name Function,Values,,PlasticHub – Mapping
|
||
OmronMX2,0001h,Target Freq,0 – 4000,,MB_R_FREQ_TARGET 1
|
||
OmronMX2,0003h,Inverter Status – A,"0: Initial status
|
||
2: Stopping
|
||
3: Running
|
||
4: Free-run stop
|
||
5: Jogging
|
||
6: DC braking
|
||
7: Retrying
|
||
8: Tripping
|
||
9: Undervoltage (UV),",,
|
||
OmronMX2,0004h,Inverter Status – B," 0: Stopping, 1: Running, 2: Tripping",,MB_R_VFD_STATUS 4
|
||
OmronMX2,0005h,Inverter Status – C,"0: –
|
||
1: Stopping
|
||
2: Decelerating
|
||
3: Constant-speed operation
|
||
4: Accelerating
|
||
5: Forward rotation
|
||
6: Reverse rotation
|
||
7: Switching from fwd.
|
||
to rev. rotation,
|
||
8: Switching from rev.
|
||
to fwd. rotation,
|
||
9: Starting fwd.
|
||
10: Starting rev.",,MB_R_VFD_STATE 3
|