| readme.md | ||
Remarks
- Framework: solid bars, using HGH/HGR rails
- Housing
- access for extruder
- Loading: 2 flexible side arms, preferably swing - to load lower, and upper zones
- Cooling: should be active by default, with a ~20T jack, 2 cooling and 2 heating zones are possible
- Heating: should be applied using profiles (ramping, using Modbus PIDs) | Partitions
- Moulds
- lower plate in AL
- mountable glass plates
- position pins/slots
- distance gauges (dowel)
- [-] ball casters
- Electronics
- burnout
- overshoot
- ssr-fail alarm/trip
- PID
- multi ramps / profiles (sound)
- cooling
- Fumes
- fixed/stationary hood & side wings, overhang at least 40cm
- integrated exhaust fan, 2x