Updating - injection/myriad-spring

This commit is contained in:
lovebird 2024-02-21 16:25:05 +01:00
parent 91a671191f
commit 47fd145099
30 changed files with 330 additions and 327 deletions

Binary file not shown.

Binary file not shown.

Binary file not shown.

Binary file not shown.

Binary file not shown.

Binary file not shown.

Binary file not shown.

File diff suppressed because one or more lines are too long

View File

@ -3,18 +3,6 @@
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\Global-Myriad-Standard.SLDASM",
"IsLaser": "1"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\310_TableMount_x4_2mm_INOX.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\309_BackShieldMountB_x6_6mm_FERRO.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\801_LegTri_x2_3mm_INOX.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\LegMounts.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\feet.SLDPRT"
},
@ -24,15 +12,30 @@
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\housing\\208_TriCover_x2_2mm_INOX.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\309_BackShieldMountB_x6_6mm_FERRO.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\801_LegTri_x2_3mm_INOX.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\301_TriRodFlange_x2_6mm_FERRO.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\303_Side_x4_6mm_FERRO.DXF.SLDPRT"
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\LegMounts.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\310_TableMount_x4_2mm_INOX.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\301_Top_x6_8mm_FERRO.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\402_BarrelMount_x1_6mm_FERRO.DXF.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\303_Side_x4_6mm_FERRO.DXF.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\302_Front_x2_6mm_FERRO.SLDPRT"
},
@ -40,98 +43,23 @@
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\300_TriMounts.SLDASM",
"IsLaser": "1"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\502_Table_x1_8mm_FERRO.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\503_SL-200-Mount_x1_6mm_FERRO.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\506_TableCover_x1_2mm_INOX.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\501_Rib_x2_6mm_FERRO.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\500_Mould-Plate.SLDASM",
"IsLaser": "1"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\701_Hopper_x1_1mm_INOX.SLDPRT",
"IsLaser": "1"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\back-post.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\framework\\Framework.SLDASM"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\402_BarrelMount_x1_6mm_FERRO.DXF.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\housing\\rod.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\TransmissionMount\\404_Middle_x1_5mm_FERRO.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\TransmissionMount\\403_Back_x2_5mm_FERRO.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\401_Side_x2_5mm_FERRO.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\TransmissionMount\\402_Front_x3_5mm_FERRO.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\TransmissionMount\\405_Bottom_x1_5mm_FERRO.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\TransmissionMount\\400_TransmissionMount.SLDASM",
"IsLaser": "1",
"Weight": "3561.42"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\303-Transmission-Single\\bracket.SLDPRT"
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\housing\\GlobalHousing.SLDASM"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\20mm-bearing-skf-6004-rs-286-7631\\20mm Bearing SKF 6004 (RS 286-7631).SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\303-Transmission-Single\\bracket.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\PlungerBushing.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Nozzle.SLDASM"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\components\\Heat_band_35.SLDPRT"
},
{
"File Path": "c:\\solidworks data\\browser\\ansi metric\\power transmission\\gears\\spur gear_amxxx11.SLDPRT",
"manufacturing-type": "none"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\components\\304_Valve-40mm\\cad\\Block.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\components\\304_Valve-40mm\\cad\\Lever-Arm.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\components\\304_Valve-40mm\\cad\\CartridgeHeater.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\components\\304_Valve-40mm\\cad\\LeverBall.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\components\\304_Valve-40mm\\cad\\M20-Circlip.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\components\\304_Valve-40mm\\cad\\Pin.SLDPRT",
"Description": "ASI 304 - 19.88D !!!"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\components\\304_Valve-40mm\\cad\\GlobalValve-40.SLDASM"
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\303-Transmission-Single\\Barrel.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\303-Transmission-Single\\fume-cover-nozzel.SLDPRT"
@ -140,10 +68,14 @@
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\303-Transmission-Single\\401-BarrelMount_x1_8mm_FERRO.DXF.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\303-Transmission-Single\\Barrel.SLDPRT"
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\303-Transmission-Single\\BarrelAssembly.SLDASM"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\303-Transmission-Single\\BarrelAssembly.SLDASM"
"File Path": "c:\\solidworks data\\browser\\ansi metric\\power transmission\\gears\\spur gear_amxxx11.SLDPRT",
"manufacturing-type": "none"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Nozzle.SLDASM"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\303-Transmission-Single\\Round_Bar_Handle.SLDPRT"
@ -151,6 +83,9 @@
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\components\\hardware\\grips\\grip-20\\ODI Clamp.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\components\\hardware\\grips\\grip-20\\ODI Ruffian Grip.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\components\\hardware\\grips\\grip-20\\McMaster - M2.5x10.SLDPRT",
"THREAD": "M2.5 x 0.45 mm Thread",
@ -161,9 +96,6 @@
"T": "Thread",
"Thread Note End": "Thread"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\components\\hardware\\grips\\grip-20\\ODI Ruffian Grip.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\components\\hardware\\grips\\grip-20\\ODI End Cap.SLDPRT"
},
@ -172,8 +104,8 @@
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\303-Transmission-Single\\HubAxle.SLDPRT",
"Weight": "301.18",
"Based On": "HubAxle"
"Based On": "HubAxle",
"Weight": "301.18"
},
{
"File Path": "c:\\solidworks data\\browser\\ansi metric\\bolts and screws\\socket head screws\\socket head cap screw_am.sldprt"
@ -184,12 +116,46 @@
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\303-Transmission-Single\\400_Drive.SLDASM"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\components\\Heat_band_35.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\303-Transmission-Single\\Plunger.SLDPRT",
"manufacturing-type": "none"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\NORELEM_030991050610\\SOLIDWORKS\\03099_1050610_5.sldprt"
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\components\\304_Valve-40mm\\cad\\Pin.SLDPRT",
"Description": "ASI 304 - 19.88D !!!"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\components\\304_Valve-40mm\\cad\\CartridgeHeater.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\components\\304_Valve-40mm\\cad\\Block.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\components\\304_Valve-40mm\\cad\\M20-Circlip.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\components\\304_Valve-40mm\\cad\\LeverBall.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\components\\304_Valve-40mm\\cad\\Lever-Arm.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\components\\304_Valve-40mm\\cad\\GlobalValve-40.SLDASM"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\components\\350_Shields\\cad-380\\361_Shield_x2_1mm_INOX.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\components\\350_Shields\\cad-380\\362_ShieldSeg_x2_1mm_INOX.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\components\\350_Shields\\cad-380\\Mirror362_ShieldSeg_x2_1mm_INOX1.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\components\\350_Shields\\cad-380\\360_ExtrusionShield.SLDASM"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\NORELEM_030991050610\\SOLIDWORKS\\03099_1050610_3.sldprt"
@ -197,37 +163,156 @@
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\NORELEM_030991050610\\SOLIDWORKS\\03099_1050610_7.sldprt"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\NORELEM_030991050610\\SOLIDWORKS\\03099_1050610_5.sldprt"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\NORELEM_030991050610\\SOLIDWORKS\\Gearlock_03099_1050610.SLDASM"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\components\\350_Shields\\cad-380\\362_ShieldSeg_x2_1mm_INOX.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\components\\350_Shields\\cad-380\\361_Shield_x2_1mm_INOX.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\components\\350_Shields\\cad-380\\Mirror362_ShieldSeg_x2_1mm_INOX.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\components\\350_Shields\\cad-380\\360_ExtrusionShield.SLDASM"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\303-Transmission-Single\\600_Transmission.SLDASM"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\housing\\Mirrorside-panel.SLDPRT"
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\701_Hopper_x1_1mm_INOX.SLDPRT",
"IsLaser": "1"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\401_Side_x2_5mm_FERRO.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\TransmissionMount\\405_Bottom_x1_5mm_FERRO.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\TransmissionMount\\403_Back_x2_5mm_FERRO.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\TransmissionMount\\402_Front_x3_5mm_FERRO.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\TransmissionMount\\404_Middle_x1_5mm_FERRO.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\TransmissionMount\\400_TransmissionMount.SLDASM",
"IsLaser": "1",
"Weight": "3447.36"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\back-post.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\framework\\Framework.SLDASM"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\503_SL-200-Mount_x1_6mm_FERRO.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\506_TableCover_x1_2mm_INOX.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\502_Table_x1_8mm_FERRO.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\501_Rib_x2_6mm_FERRO.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\500_Mould-Plate.SLDASM",
"IsLaser": "1"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\handwheel-15.snapshot.6\\handwheel.SLDPRT"
},
{
"File Path": "c:\\solidworks data\\browser\\ansi metric\\bolts and screws\\socket head screws\\socket button head cap screw_am.sldprt"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\TransmissionMount\\BarrelGuide.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\housing\\205_Door_x2_1mm_INOX.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\housing\\Mirrorside-panel.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126640490-7-63242000-364-8223\\63242000_05.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126640490-7-63242000-364-8223\\63242000_02.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126640490-7-63242000-364-8223\\63242000_03.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126640490-7-63242000-364-8223\\63242000_04.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126640490-7-63242000-364-8223\\63242000_06.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126640490-7-63242000-364-8223\\63242000_01.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126640490-7-63242000-364-8223\\63242000.SLDASM"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\components\\shared\\3Pos-Switch-22mm.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\E5CC_Solidworks\\E5CC_BASE.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\E5CC_Solidworks\\Y92F_49.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\E5CC_Solidworks\\E5CC_PACKING.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\E5CC_Solidworks\\E5CC.SLDASM"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\components\\shared\\LED_button_green.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\solid-state-relay-heat-sink\\Solid State Relay Heat Sink, SSR-40DD.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\iec-320-c14\\IEC320-C14RCPT.SLDPRT",
"ID": "MP0001041698",
"Vendor": "QUALTEK",
"Serialize": "NO",
"Routing": "NO",
"UID": "MP0001041698",
"Unique Identification Number": "MP0001041698",
"UniqueIdentificationNumber": "MP0001041698"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\ControlBox.SLDASM"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\housing\\202_SideL_x1_2mm_INOX.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\housing\\204_Front_x1_2mm_INOX.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\housing\\203_Top_x1_2mm_INOX.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\housing\\202-Bottom_x1_2mm_INOX.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\hvac\\edf-70mm\\conguser.SLDPRT",
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\hvac\\edf-70mm\\ring.SLDPRT",
"Масса": "0.00",
"Материал": "Настроенная пользователем пластмасса",
"Материал": "1.5714 (16NiCr4)",
"Раздел": "Детали",
"Вид_документа": "Электронная модель детали",
"Код_документа": "МД",
роцент_завершения": "0"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\hvac\\edf-70mm\\body.SLDPRT",
"Масса": "0.05",
"Материал": "Нейлон",
"Раздел": "Детали",
"Вид_документа": "Электронная модель детали",
"Код_документа": "МД",
@ -246,9 +331,9 @@
"File Path": "c:\\solidworks data\\browser\\ansi metric\\bolts and screws\\machine screws\\pan cross head_am.sldprt"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\hvac\\edf-70mm\\ring.SLDPRT",
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\hvac\\edf-70mm\\cowl.SLDPRT",
"Масса": "0.00",
"Материал": "1.5714 (16NiCr4)",
"Материал": "АБС-2020, черный",
"Раздел": "Детали",
"Вид_документа": "Электронная модель детали",
"Код_документа": "МД",
@ -263,27 +348,18 @@
"Код_документа": "МД",
роцент_завершения": "0"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\hvac\\edf-70mm\\body.SLDPRT",
"Масса": "0.05",
"Материал": "Нейлон",
"Раздел": "Детали",
"Вид_документа": "Электронная модель детали",
"Код_документа": "МД",
роцент_завершения": "0"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\hvac\\edf-70mm\\cowl.SLDPRT",
"Масса": "0.00",
"Материал": "АБС-2020, черный",
"Раздел": "Детали",
"Вид_документа": "Электронная модель детали",
"Код_документа": "МД",
роцент_завершения": "0"
},
{
"File Path": "c:\\solidworks data\\browser\\ansi metric\\nuts\\hex nuts\\hex nut style 1_am.sldprt"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\hvac\\edf-70mm\\conguser.SLDPRT",
"Масса": "0.00",
"Материал": "Настроенная пользователем пластмасса",
"Раздел": "Детали",
"Вид_документа": "Электронная модель детали",
"Код_документа": "МД",
роцент_завершения": "0"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\hvac\\edf-70mm\\EDF impeller 70mm 12blades.SLDASM",
"Масса": "0.12",
@ -292,107 +368,31 @@
"Код_документа": "МС",
роцент_завершения": "0"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126647935-7-63238000-3648188\\63238000_02.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126647935-7-63238000-3648188\\63238000_01.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126647935-7-63238000-3648188\\63238000_05.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126647935-7-63238000-3648188\\63238000_03.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126647935-7-63238000-3648188\\63238000_04.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126647935-7-63238000-3648188\\63238000_06.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126647935-7-63238000-3648188\\63238000_03.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126647935-7-63238000-3648188\\63238000_05.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126647935-7-63238000-3648188\\63238000_01.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126647935-7-63238000-3648188\\63238000_02.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126647935-7-63238000-3648188\\63238000.SLDASM"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\housing\\204_Front_x1_2mm_INOX.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\housing\\203_Top_x1_2mm_INOX.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\housing\\202_SideL_x1_2mm_INOX.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126640490-7-63242000-364-8223\\63242000_02.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126640490-7-63242000-364-8223\\63242000_04.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126640490-7-63242000-364-8223\\63242000_01.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126640490-7-63242000-364-8223\\63242000_03.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126640490-7-63242000-364-8223\\63242000_06.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126640490-7-63242000-364-8223\\63242000_05.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126640490-7-63242000-364-8223\\63242000.SLDASM"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\components\\shared\\3Pos-Switch-22mm.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\E5CC_Solidworks\\Y92F_49.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\E5CC_Solidworks\\E5CC_BASE.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\E5CC_Solidworks\\E5CC_PACKING.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\E5CC_Solidworks\\E5CC.SLDASM"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\iec-320-c14\\IEC320-C14RCPT.SLDPRT",
"ID": "MP0001041698",
"Vendor": "QUALTEK",
"Serialize": "NO",
"Routing": "NO",
"UID": "MP0001041698",
"Unique Identification Number": "MP0001041698",
"UniqueIdentificationNumber": "MP0001041698"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\solid-state-relay-heat-sink\\Solid State Relay Heat Sink, SSR-40DD.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\components\\shared\\LED_button_green.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\ControlBox.SLDASM"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\housing\\200_GlobalHousingMaster.SLDASM"
},
{
"File Path": "c:\\solidworks data\\browser\\ansi metric\\bolts and screws\\socket head screws\\socket button head cap screw_am.sldprt"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\housing\\211_Table_x1_2mm_INOX.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\housing\\GlobalHousing.SLDASM"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\handwheel-15.snapshot.6\\handwheel.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\TransmissionMount\\BarrelGuide.SLDPRT"
}
]

Binary file not shown.

Binary file not shown.

View File

@ -3,13 +3,40 @@
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\housing\\200_GlobalHousingMaster.SLDASM"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\housing\\Mirrorside-panel.SLDPRT"
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\housing\\203_Top_x1_2mm_INOX.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\housing\\205_Door_x2_1mm_INOX.SLDPRT"
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\housing\\204_Front_x1_2mm_INOX.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\housing\\202_SideL_x1_2mm_INOX.SLDPRT"
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\housing\\202-Bottom_x1_2mm_INOX.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126640490-7-63242000-364-8223\\63242000_03.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126640490-7-63242000-364-8223\\63242000_01.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126640490-7-63242000-364-8223\\63242000_02.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126640490-7-63242000-364-8223\\63242000_04.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126640490-7-63242000-364-8223\\63242000_06.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126640490-7-63242000-364-8223\\63242000_05.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126640490-7-63242000-364-8223\\63242000.SLDASM"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\solid-state-relay-heat-sink\\Solid State Relay Heat Sink, SSR-40DD.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\components\\shared\\LED_button_green.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\components\\shared\\3Pos-Switch-22mm.SLDPRT"
@ -26,33 +53,6 @@
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\E5CC_Solidworks\\E5CC.SLDASM"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126640490-7-63242000-364-8223\\63242000_03.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126640490-7-63242000-364-8223\\63242000_05.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126640490-7-63242000-364-8223\\63242000_06.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126640490-7-63242000-364-8223\\63242000_04.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126640490-7-63242000-364-8223\\63242000_01.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126640490-7-63242000-364-8223\\63242000_02.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126640490-7-63242000-364-8223\\63242000.SLDASM"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\solid-state-relay-heat-sink\\Solid State Relay Heat Sink, SSR-40DD.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\components\\shared\\LED_button_green.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\iec-320-c14\\IEC320-C14RCPT.SLDPRT",
"ID": "MP0001041698",
@ -66,17 +66,14 @@
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\ControlBox.SLDASM"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\housing\\204_Front_x1_2mm_INOX.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126647935-7-63238000-3648188\\63238000_01.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126647935-7-63238000-3648188\\63238000_03.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126647935-7-63238000-3648188\\63238000_04.SLDPRT"
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126647935-7-63238000-3648188\\63238000_02.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126647935-7-63238000-3648188\\63238000_01.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126647935-7-63238000-3648188\\63238000_05.SLDPRT"
@ -85,16 +82,28 @@
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126647935-7-63238000-3648188\\63238000_06.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126647935-7-63238000-3648188\\63238000_02.SLDPRT"
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126647935-7-63238000-3648188\\63238000_04.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\Electronics\\126647935-7-63238000-3648188\\63238000.SLDASM"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\housing\\202-Bottom_x1_2mm_INOX.SLDPRT"
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\housing\\202_SideL_x1_2mm_INOX.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\housing\\203_Top_x1_2mm_INOX.SLDPRT"
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\housing\\Mirrorside-panel.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\housing\\205_Door_x2_1mm_INOX.SLDPRT"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\hvac\\edf-70mm\\body.SLDPRT",
"Масса": "0.05",
"Материал": "Нейлон",
"Раздел": "Детали",
"Вид_документа": "Электронная модель детали",
"Код_документа": "МД",
роцент_завершения": "0"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\hvac\\edf-70mm\\blades.SLDPRT",
@ -118,12 +127,9 @@
роцент_завершения": "0"
},
{
"File Path": "c:\\solidworks data\\browser\\ansi metric\\bolts and screws\\machine screws\\pan cross head_am.sldprt"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\hvac\\edf-70mm\\body.SLDPRT",
"Масса": "0.05",
"Материал": "Нейлон",
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\hvac\\edf-70mm\\cowl.SLDPRT",
"Масса": "0.00",
"Материал": "АБС-2020, черный",
"Раздел": "Детали",
"Вид_документа": "Электронная модель детали",
"Код_документа": "МД",
@ -148,13 +154,7 @@
роцент_завершения": "0"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\hvac\\edf-70mm\\cowl.SLDPRT",
"Масса": "0.00",
"Материал": "АБС-2020, черный",
"Раздел": "Детали",
"Вид_документа": "Электронная модель детали",
"Код_документа": "МД",
роцент_завершения": "0"
"File Path": "c:\\solidworks data\\browser\\ansi metric\\bolts and screws\\machine screws\\pan cross head_am.sldprt"
},
{
"File Path": "C:\\Users\\mc007\\Desktop\\osr\\products\\products\\injection\\myriad-spring\\cad\\parts\\hvac\\edf-70mm\\EDF impeller 70mm 12blades.SLDASM",

Binary file not shown.

Binary file not shown.

File diff suppressed because one or more lines are too long

Binary file not shown.

Binary file not shown.

Binary file not shown.

Binary file not shown.

File diff suppressed because one or more lines are too long

Binary file not shown.

BIN
injection/myriad-spring/renderings/myriad.jpg (Stored with Git LFS) Normal file

Binary file not shown.