# Multichannel PID controller Purpose of this PID controller is to lower overall amperage by cycling periodically through SSRs. This is based on [osPID](http://ospid.com/blog/download/) ### Hardware - [Controllino - Mega (Arduino compatible)](https://www.controllino.biz/product/controllino-mega/). [See PIN layout](./vendor/controllino/CONTROLLINO-MEGA-Pinout-1.jpg) ![](./vendor/controllino/mega.jpg) - Optional: OLED & keypad control - 8 channels - Optional: Modbus - TC sensor module, MAX6675 | MAX31855 ## Features ### PID - Autotune per PID - Support for multiple TCs (see Marlin firmware) ### Configuration - Set max Amp - Set max/min heat time per cell/partition ## Milestones / Todos - [x] Check/Simulate performance bottle necks for Mega - [ ] Temperature logger, serial & MaxC based - [ ] Integrate PID/Auto-tune - [ ] EEprom storage ? - [ ] Debug interface via RS485 - [ ] Data - reader via RS232 (Matlab) - [ ] Configuration (remote / local) -> Control-Freak - HMI - [ ] Model testing/verification ## Edge cases / Errors - [ ] PID-Partition Timeout : PID didn't reach target with limits - [ ] PID/Partition Overshooting : PID or operator malfunction - [ ] PID Auto-tuning timeout : autotuning too long - [ ] PID/Partition interference : partition overlap noise ? ## Modes - [ ] Groups (partition groups) - [ ] Serial (single linked partition group) - [ ] Remote (HMI & control) ## PP/PH ### New parameters - [ ] Ramp-time - [ ] Amp Budget ### New beahviours - [ ] Currently there are multiple issues surfacing regarding the sheetpress. A profile should allow to have multiple target temperature points (eg: 1 hour to hold softening point, 30 mins for holding melting point rage, 10 mins for slightly over melting point : pressing phase) with a holding & ramp time each. - [ ] The user should be able to adjust these profiles per flake size. For that we should also study the effects of various flake sizes regarding stresses created in the sheets. ### References - [PID research](https://github.com/plastic-hub/research#pid-control) #### [PP Print-Head System](https://github.com/plastic-hub/lydia-print-head) According to the manual [OMRON - E5DC / E5DC-B](http://omrondoc.ru/C/H175-E1-08.pdf), we have - 2 control points - Internal Set Point*1 - Manual MV - Remote SP Monitor - MV Monitor (Heating & Cooling) - Dead Band - Derivative Time (Cooling & Heating) - Integral Time (Cooling & Heating) - Hysteresis (Cooling & Heating) - Control Period (Heating) and lots more settings to influence heating, ramp and cooling behavior via Modbus. ```@todo```, repeat amp budgets tests with tis controller