--- tag: m0048 title: Probe Repeatability Test brief: Measure Z Probe repeatability. author: thinkyhead requires: Z_MIN_PROBE_REPEATABILITY_TEST group: calibration codes: [ M48 ] notes: - Requires `Z_MIN_PROBE_REPEATABILITY_TEST`. parameters: - tag: C optional: true description: Probe with temperature compensation enabled (`PTC_PROBE`, `PTC_BED`, `PTC_HOTEND`) values: - type: bool default: 1 - tag: E optional: true description: Engage for each probe values: - tag: engage type: bool - tag: L optional: true description: Number of legs to probe values: - tag: legs type: int - tag: P optional: true description: Number of probes to do values: - tag: count type: int - tag: S optional: true description: Star/Schizoid probe. By default this will do 7 points. Override with `L`. values: - tag: 0 description: Circular pattern - tag: 1 description: Star-like pattern - tag: V optional: true description: Verbose Level (0-4, default=1) values: - tag: level type: int - tag: X optional: true description: X Position values: - tag: pos type: float - tag: Y optional: true description: Y Position values: - tag: pos type: float examples: --- Probes come in many flavors and as such have varying levels of accuracy, reliability, and repeatability, depending on several factors. This command tests the probe for repeatability (precision) and produces a standard deviation based on two or more probes of the same XY position.