flexi-bot/docs/marlin/_gcode/M208.md
2023-09-05 20:38:49 +02:00

66 lines
1.7 KiB
Markdown

---
tag: m0208
title: Firmware Recover
brief: Firmware-retraction recover settings.
author: thinkyhead
requires: FWRETRACT
group: motion
codes: [ M208 ]
notes:
- Requires `FWRETRACT`.
- See related codes [`G10`](/docs/gcode/G010.html), [`G11`](/docs/gcode/G010.html), [`M207`](/docs/gcode/M207.html), and [`M209`](/docs/gcode/M209.html).
parameters:
-
tag: S
optional: true
description: Additional recover length. Can be negative to reduce recover length.
values:
-
tag: length
type: float
-
tag: W
optional: true
description: Additional recover swap length. Can be negative to reduce the length.
values:
-
tag: length
type: float
-
tag: F
optional: true
description: Recover feedrate (units/min)
values:
-
tag: feedrate
type: float
-
tag: R
optional: true
description: Swap recover feedrate (units/min)
values:
-
tag: feedrate
type: float
examples:
-
pre: Set recover extra length to 0.2mm and recover feedrate to 10mm/s
code: M208 S0.2 F600
-
pre: Set a retract length of 2mm and *total* recover length of 2.5mm
code:
- M207 S2.0 ; 2.0mm retract
- M208 S0.5 ; 2.0mm + 0.5mm recover
---
Set the added lengths and feedrates for firmware-based retract recovery. The lengths set by [`M208`](/docs/gcode/M208.html) are applied *in addition* to the lengths set by [`M207`](/docs/gcode/M207.html) when un-retracting (aka "recovering") the filament. The new values will apply to all subsequent [`G11`](/docs/gcode/G011.html) commands.
The "swap" values apply to firmware-based recover moves after a tool-change.