tag: m0672
title: Duet Smart Effector sensitivity
brief: Set Duet Smart Effector sensitivity
author: shitcreek
since: 2.0.2
requires: DUET_SMART_EFFECTOR
group: control
codes: [ M672 ]
notes:
- In addition to the `DUET_SMART_EFFECTOR` option, a defined `SMART_EFFECTOR_MOD_PIN` is also required.
- The format of `M672` in Marlin differs from [Duet Smart Effector documentation](//duet3d.dozuki.com/Wiki/Smart_effector_and_carriage_adapters_for_delta_printer).
- Use only one of the two parameters (`S` or `R`).
parameters:
-
tag: S
optional: true
description: "Set sensitivity (0-255)"
values:
-
tag: sensitivity
type: int
-
tag: R
optional: true
description: "Revert sensitivity to factory settings"
values:
-
type: bool
example:
-
pre: Set sensitivity to 255
code: M672 S255
---
Set or reset Duet Smart Effector sensitivity.