flexi-bot/docs/marlin/_gcode/M916.md
2023-09-05 20:38:49 +02:00

2.8 KiB

tag title brief author requires group codes related notes parameters
m0916 L6474 Thermal Warning Test Find L6474 drive level (KVAL_HOLD) threshold shitcreek MONITOR_L6470_DRIVER_STATUS L6474
M916
M917
M918
Requires `MONITOR_L6470_DRIVER_STATUS`.
All tests assume each axis uses matching driver chips.
On the L6474 the TVAL is used instead of KVAL.
tag optional description values
J true Select which driver(s) to monitor on multi-driver axis
tag description
0 (default) Monitor all drivers on the axis
tag description
1 Monitor only X, Y, Z, E1
tag description
2 Monitor only X2, Y2, Z2, E2
tag description
3 Monitor only Z3, E3
tag description
4 Monitor only Z4, E4
tag description
5 Monitor only Z5, E5
tag description
6 Monitor only Z6, E6
tag description
7 Monitor only Z7, E7
tag optional description values
X true Monitor X with the given displacement (1 - 255mm) on either side of the current position.
type
mm
tag optional description values
Y true Monitor Y with the given displacement (1 - 255mm) on either side of the current position.
type
mm
tag optional description values
Z true Monitor Z with the given displacement (1 - 255mm) on either side of the current position.
type
mm
tag optional description values
E true Monitor E with the given displacement (1 - 255mm) on either side of the current position.
type
mm
tag optional description values
F true Feedrate for the moves. (Default max feedrate if unspecified.)
tag type
feedrate int
tag optional description values
T true Current (mA) setting for TVAL (0 - 4A in 31.25mA increments, rounds down) - L6474 only. If unspecified, report current value from driver.
tag type
current int
tag optional description values
K true Value for KVAL_HOLD (0 - 255) (ignored for L6474). If unspecified, report current value from driver.
tag type
Kvalue int
tag optional description values
D true Time (in seconds) to run each setting of KVAL_HOLD/TVAL. (Default zero, to run each setting once.)
tag type
second int