59 lines
1.1 KiB
Markdown
59 lines
1.1 KiB
Markdown
---
|
|
tag: m0145
|
|
title: Set Material Preset
|
|
brief: Set material presets in the LCD menu.
|
|
author: thinkyhead
|
|
|
|
requires: NEWPANEL
|
|
group: lcd
|
|
|
|
codes: [ M145 ]
|
|
|
|
notes:
|
|
- Requires an LCD controller.
|
|
- View the current settings with [`M503`](/docs/gcode/M503.html).
|
|
- If `EEPROM_SETTINGS` is enabled, these settings are saved with [`M500`](/docs/gcode/M500.html), loaded with [`M501`](/docs/gcode/M501.html), and reset with [`M502`](/docs/gcode/M502.html).
|
|
|
|
parameters:
|
|
-
|
|
tag: S
|
|
optional: true
|
|
description: Material index
|
|
values:
|
|
-
|
|
tag: index
|
|
type: int
|
|
-
|
|
tag: H
|
|
optional: true
|
|
description: Hotend temperature
|
|
values:
|
|
-
|
|
tag: temp
|
|
type: int
|
|
-
|
|
tag: B
|
|
optional: true
|
|
description: Bed temperature
|
|
values:
|
|
-
|
|
tag: temp
|
|
type: int
|
|
-
|
|
tag: F
|
|
optional: true
|
|
description: Fan speed
|
|
values:
|
|
-
|
|
tag: speed
|
|
type: byte
|
|
|
|
examples:
|
|
-
|
|
pre: Set heatup presets for material 1
|
|
code: M145 S0 H190 B70 F50
|
|
|
|
---
|
|
|
|
Set the preheating presets for materials in the LCD menu.
|