flexi-bot/docs/marlin/_gcode/M192.md
2023-09-05 20:38:49 +02:00

40 lines
817 B
Markdown

---
tag: m0192
title: Wait for Probe temperature
brief: Wait for the probe temperature sensor to reach a target
author: thinkyhead
requires: PROBE_TEMP_COMPENSATION
group: calibration
since: 2.0.6.2
codes: [ M192 ]
related: [ G76, M871 ]
parameters:
-
tag: R
optional: true
description: Temperature to wait for, whether heating or cooling.
values:
-
tag: temp
type: int
-
tag: S
optional: true
description: A minimum temperature to wait for. No wait if already higher.
values:
-
tag: temp
type: int
example:
-
code:
- M192 S44 ; Wait for probe temperature to go above 44C
- M192 R28 ; Wait for probe temperature to get close to 28C
---
Use this command to dwell until the probe reaches a given target temperature.