74 lines
1.6 KiB
Markdown
74 lines
1.6 KiB
Markdown
---
|
|
tag: m0912
|
|
title: Clear TMC OT Pre-Warn
|
|
brief: Clear overtemperature pre-warn condition flag
|
|
author: thinkyhead
|
|
|
|
requires: TMC2130|TMC2208|TMC2209|TMC2660, MONITOR_DRIVER_STATUS
|
|
group: control
|
|
|
|
codes: [ M912 ]
|
|
|
|
notes: Requires one or more TMC stepper drivers.
|
|
|
|
parameters:
|
|
-
|
|
tag: I
|
|
optional: true
|
|
since: 1.1.9
|
|
description: Stepper number to set. If omitted, all specified axes.
|
|
values:
|
|
-
|
|
tag: 0
|
|
description: Both.
|
|
-
|
|
tag: 1
|
|
description: Base (X, Y, Z) steppers.
|
|
-
|
|
tag: 2
|
|
description: Second (X2, Y2, Z2) steppers.
|
|
-
|
|
tag: 3
|
|
description: Third (Z3) steppers.
|
|
-
|
|
tag: X
|
|
type: int
|
|
optional: true
|
|
description: Clear `X` and/or `X2` stepper driver Over Temperature Pre-warn flag.
|
|
-
|
|
tag: Y
|
|
type: int
|
|
optional: true
|
|
description: Clear `Y` and/or `Y2` stepper driver Over Temperature Pre-warn flag.
|
|
-
|
|
tag: Z
|
|
type: int
|
|
optional: true
|
|
description: Clear `Z` and/or `Z2` and/or `Z3` stepper driver Over Temperature Pre-warn flag.
|
|
-
|
|
tag: E
|
|
type: int
|
|
optional: true
|
|
description: Clear all or one `E` stepper driver Over Temperature Pre-warn flag.
|
|
values:
|
|
-
|
|
tag: "-"
|
|
description: All E.
|
|
-
|
|
tag: 0-4
|
|
description: E index.
|
|
|
|
examples:
|
|
-
|
|
code: |
|
|
M912 ; clear all
|
|
M912 X ; clear X and X2
|
|
M912 X1 ; clear X1 only
|
|
M912 X2 ; clear X2 only
|
|
M912 X E ; clear X, X2, and all E
|
|
M912 E1 ; clear E1 only
|
|
|
|
---
|
|
|
|
Clear the stepper driver overtemperature pre-warn condition flag.
|