Modbus Implementation Analysis & TODOs
1. Executive Summary
The current Modbus RTU and TCP implementation is functional but suffers from several architectural issues that impact performance, scalability, and reliability. Key problems include inefficient data lookups due to linear searches, overly complex and redundant state management abstractions, and a lack of support for transactional operations.
This document outlines these issues and provides a roadmap for both immediate, tactical improvements and long-term strategic changes to create a faster, more robust, and transactional Modbus subsystem.
2. Identified Issues & Bottlenecks
2.1. Useless Abstractions & State Duplication
The separation between ModbusRTU's cache (SlaveData, ModbusValueEntry) and the RTU_Base/RegisterState classes creates an unnecessary and confusing layer of abstraction.
- State is duplicated: The value of a register is stored in both a
ModbusValueEntryinsideModbusRTUand aRegisterStateobject owned by aRTU_Basedevice. This increases memory usage and creates synchronization complexity. - Complex Data Flow: An update flows from the
ModbusRTUcache, triggers a callback to theManager, which then finds theRTU_Basedevice, which then updates its internalRegisterState. This is indirect and inefficient. - High Overhead: The
RTU_BaseandRegisterStateclasses introduce significant object-oriented overhead for what is fundamentally a simple register map. Each register becomes a heap-allocated object, which can be slow and lead to memory fragmentation on an embedded system.
This abstraction is "useless" because it doesn't provide significant benefits to outweigh its complexity and performance costs. A flatter, more direct data model is needed.
2.2. Inefficient Data Lookups (Performance Bottleneck)
Multiple critical code paths rely on linear iteration through arrays to find data. This is a major performance bottleneck, especially as the number of slaves and registers grows.
ModbusRTU::findCoilEntry/findRegisterEntry: Iterates throughMAX_ADDRESSES_PER_SLAVEentries to find a cached value.ModbusTCP::findMappingForAddress: Iterates through all registeredMB_Registersblocks to map a TCP address.Manager::getDeviceById: Iterates through an array to find a device pointer.
These O(n) operations are called frequently and will slow down the entire system under load.
2.3. Non-Transactional Operations
The user explicitly requested "transactional" capabilities. The current system is not transactional. Each read/write is a discrete operation queued and executed independently. There is no mechanism to:
- Group multiple operations (e.g., a read-modify-write sequence) to ensure they execute without interruption.
- Roll back a series of operations if one fails.
- Ensure a consistent view of data across multiple registers at a single point in time.
This makes it difficult to implement complex control logic that relies on atomic updates to multiple registers.
2.4. Sequential Operation Queue (Performance Bottleneck)
The ModbusRTU::operationQueue is processed sequentially by the main loop(). The handlePendingOperations function finds and executes only one operation per call. This can lead to high latency for operations if the queue is long, as each operation must wait for the minOperationInterval plus the processing time of all preceding operations.
3. Short-Term Solutions (Tactical Fixes)
These solutions can be implemented quickly to get immediate performance gains.
3.1. Solution: Optimize Data Lookups
Replace the linear search for cached register values in ModbusRTU with a more efficient data structure. Since this is an embedded system, we should avoid dynamic memory allocation found in std::map. A statically-allocated hash map is a good compromise.
Code Example: A simple hash map for SlaveData
This requires modifying ModbusTypes.h to change the SlaveData structure.
// ... existing code ...
#include "constants.h"
#include "config-modbus.h"
// --- HASH MAP CONFIG FOR SLAVE DATA ---
#define SLAVE_DATA_MAP_SIZE (MAX_ADDRESSES_PER_SLAVE * 2) // Simple hash map size
// Structure to represent a register or coil value entry
struct ModbusValueEntry
{
// ... existing code ...
uint16_t address; // 2 bytes
uint16_t value; // 2 bytes
uint8_t flags; // 1 byte for flags (used, synchronized)
ModbusValueEntry* next; // Pointer for separate chaining in case of collision
// ... existing code ...
ModbusValueEntry()
: lastUpdate(0), address(0), value(0), flags(0), next(nullptr) {}
ModbusValueEntry(uint16_t addr, uint16_t val, bool sync = true)
: lastUpdate(millis()), address(addr), value(val), flags(0), next(nullptr)
// ... existing code ...
};
// Structure to represent a Modbus slave's data
struct SlaveData
{
// --- NEW HASH MAP IMPLEMENTATION ---
ModbusValueEntry entryPool[MAX_ADDRESSES_PER_SLAVE * 2]; // Pool of entries for coils and registers
ModbusValueEntry* coilMap[SLAVE_DATA_MAP_SIZE];
ModbusValueEntry* registerMap[SLAVE_DATA_MAP_SIZE];
uint16_t entryPoolIndex;
// --- END NEW HASH MAP ---
uint8_t coilCount;
uint8_t registerCount;
uint8_t slaveId;
SlaveData() : entryPoolIndex(0), coilCount(0), registerCount(0), slaveId(0)
{
clear();
}
void clear()
{
entryPoolIndex = 0;
coilCount = 0;
registerCount = 0;
slaveId = 0;
// Initialize hash maps to nullptr
for (int i = 0; i < SLAVE_DATA_MAP_SIZE; ++i) {
coilMap[i] = nullptr;
registerMap[i] = nullptr;
}
// Invalidate all entries in the pool
for (int i = 0; i < MAX_ADDRESSES_PER_SLAVE * 2; ++i) {
CBI(entryPool[i].flags, OP_USED_BIT);
}
}
// Simple hash function
static uint16_t hash(uint16_t address) {
return address % SLAVE_DATA_MAP_SIZE;
}
};
// ... existing code ...
You would then update ModbusRTU::findRegisterEntry, createRegisterEntry and their coil counterparts to use this hash map, which would change the lookup from O(n) to O(1) on average.
3.2. Solution: Flatten the Abstraction
Deprecate the RTU_Base and RegisterState classes for state management. Interact with the ModbusRTU cache directly from your main application logic or components. This eliminates state duplication and simplifies the data flow significantly.
Code Example: Direct interaction
// In your main application logic or a component that needs to write a value
void setHeaterTemperature(ModbusRTU& modbus, uint8_t slaveId, uint16_t temp)
{
uint16_t address = 0x100A; // Address for heater setpoint
// The component logic now directly queues the write operation.
// The ModbusRTU class handles caching, retries, etc.
modbus.writeRegister(slaveId, address, temp);
}
// In your main loop, to read a value
void checkHeaterStatus(ModbusRTU& modbus, uint8_t slaveId)
{
uint16_t address = 0x200B; // Address for heater status
uint16_t status;
// Directly get the value from the ModbusRTU cache.
// The return value indicates if the value is available in the cache.
if (modbus.getRegisterValue(slaveId, address, status)) {
if (status == 1) {
// Heater is on
}
} else {
// Value not yet synchronized, maybe queue a read
modbus.readRegister(slaveId, address);
}
}
This change simplifies the architecture by removing an entire layer of objects and indirect calls.
4. Long-Term Solutions (Strategic Changes)
4.1. Solution: Implement Transactional Operations
Modify the queuing mechanism to support transactions. A transaction would be an atomic group of operations.
- Define a
ModbusTransactionstruct: This struct would contain an array ofModbusOperations. - Change the Queue: The
operationQueueinModbusRTUwould become a queue ofModbusTransactionpointers. - Update
handlePendingOperations: The loop would grab the next transaction from the queue and execute all operations within it sequentially, without allowing other operations to interrupt. If any operation in the transaction fails, the entire transaction is marked as failed.
Conceptual Code:
// In ModbusTypes.h
struct ModbusTransaction {
ModbusOperation operations[MAX_OPS_PER_TRANSACTION];
uint8_t opCount;
// ... other metadata like transaction ID, status, etc.
};
// In ModbusRTU.h
class ModbusRTU {
// ...
private:
ModbusTransaction transactionQueue[MAX_PENDING_TRANSACTIONS];
// ...
};
This architectural change is significant but is the only robust way to meet the "transactional" requirement.
4.2. Solution: Overhaul State Management
As a long-term goal, create a single, unified data model for all Modbus state (both RTU and TCP). This could be a "global register map" implemented as a single contiguous block of memory or a more sophisticated data structure.
- Single Source of Truth: All components read from and write to this central map.
- Efficient Access: The map would be indexed directly by address, providing O(1) access.
- Gateway Logic: The
ModbusTCPandModbusRTUclasses become stateless gateways that simply translate requests into reads/writes on this central map. - Synchronization: A separate mechanism (like a dirty flag system) would trigger RTU writes when values in the map are changed by the application logic.
This would represent a fundamental shift from the current object-oriented, distributed state model to a centralized, data-centric one, leading to massive gains in performance and simplicity.
5. Bidirectional Data Flow Diagrams
Based on the refined architecture (App -> NetworkComponent -> NetworkValue), these diagrams model the two primary data flow directions.
5.1. Data Flow: From Device to Controller (RTU -> TCP)
This diagram shows how a value read from a physical RTU device gets updated internally, making it available for a Modbus TCP client to read.
sequenceDiagram
participant Physical Device
participant ModbusRTU
participant PHApp
participant NetworkComponent as OmronE5
participant NetworkValue
Note over Physical Device, NetworkValue: Goal: Update NetworkValue with new sensor reading from device.
ModbusRTU->>Physical Device: Queues and sends read request (e.g., Read Holding Registers)
Physical Device-->>ModbusRTU: Responds with data
activate ModbusRTU
ModbusRTU->>ModbusRTU: onDataReceived(message, token)
ModbusRTU->>ModbusRTU: _processReadResponse(op, message)
ModbusRTU->>ModbusRTU: updateRegisterValue(slaveId, addr, newValue)
Note right of ModbusRTU: Cache is updated and change is detected.
ModbusRTU->>PHApp: onRegisterChangeCallback(op, oldValue, newValue)
deactivate ModbusRTU
activate PHApp
PHApp->>PHApp: Find component by op.slaveId (e.g., OmronE5 instance)
PHApp->>NetworkComponent: onRegisterUpdate(op.address, newValue)
deactivate PHApp
activate NetworkComponent
NetworkComponent->>NetworkComponent: Map RTU address to correct NetworkValue
NetworkComponent->>NetworkValue: update(newValue)
deactivate NetworkComponent
activate NetworkValue
NetworkValue->>NetworkValue: Check against threshold, update internal state
Note right of NetworkValue: The value is now updated and ready for TCP clients.
deactivate NetworkValue
5.2. Data Flow: From Controller to Device (TCP -> RTU)
This diagram shows how a write command from a Modbus TCP client gets propagated down to the physical RTU device.
sequenceDiagram
participant TCP Client
participant ModbusTCP
participant PHApp
participant NetworkComponent as OmronE5
participant ModbusRTU
Note over TCP Client, ModbusRTU: Goal: Write a new setpoint from a client to the physical device.
TCP Client->>ModbusTCP: Write request (e.g., Write Single Register at TCP Address)
activate ModbusTCP
ModbusTCP->>ModbusTCP: writeSingleHregWorker(request)
ModbusTCP->>ModbusTCP: findMappingForAddress(tcpAddress)
Note right of ModbusTCP: Mapping contains the target componentId.
ModbusTCP->>PHApp: byId(componentId)
deactivate ModbusTCP
activate PHApp
PHApp->>NetworkComponent: mb_tcp_write(reg, value)
deactivate PHApp
activate NetworkComponent
NetworkComponent->>NetworkComponent: Map TCP address to internal action (e.g., setSP)
NetworkComponent->>ModbusRTU: writeRegister(slaveId, rtuAddress, value)
Note right of NetworkComponent: Component logic translates TCP write to an RTU write request.
deactivate NetworkComponent
activate ModbusRTU
ModbusRTU->>ModbusRTU: queueOperation(op)
Note right of ModbusRTU: The write operation is now in the queue.
deactivate ModbusRTU
loop RTU Processing Loop
ModbusRTU->>ModbusRTU: process()
ModbusRTU->>ModbusRTU: handlePendingOperations()
ModbusRTU->>Physical Device: Sends the write command
end
6. Verifying a Transaction (setSP Example)
Verifying that a write operation is truly complete requires more than just sending a command. A robust verification process confirms that the device has not only acknowledged the command but has also correctly updated its internal state. The most reliable method for this is a Read-After-Write sequence.
This process involves two phases:
- Write Acknowledgment: Confirming the device received the write command.
- Value Confirmation: Reading the value back from the device to ensure it matches the value that was written.
The following diagram illustrates this closed-loop verification flow for setting an Omron SP.
sequenceDiagram
participant AppLogic as "App Logic (e.g., OmronE5)"
participant ModbusRTU
participant PhysicalDevice as "Omron Device"
Note over AppLogic, PhysicalDevice: Goal: Set SP to 150 and verify it was written correctly.
AppLogic->>ModbusRTU: writeRegister(slaveId, SP_Address, 150)
AppLogic->>AppLogic: state = WAITING_WRITE_ACK; pendingSP = 150
ModbusRTU->>PhysicalDevice: Sends write command
PhysicalDevice-->>ModbusRTU: Write Acknowledged
activate ModbusRTU
ModbusRTU->>ModbusRTU: onDataReceived() for write
ModbusRTU->>AppLogic: onWriteCallback(op for SP write)
deactivate ModbusRTU
activate AppLogic
AppLogic->>AppLogic: if (op.address == SP_Address and state == WAITING_WRITE_ACK)
AppLogic->>ModbusRTU: readRegister(slaveId, SP_Address)
AppLogic->>AppLogic: state = WAITING_READ_VERIFY
deactivate AppLogic
ModbusRTU->>PhysicalDevice: Sends read command
PhysicalDevice-->>ModbusRTU: Responds with SP value
activate ModbusRTU
ModbusRTU->>ModbusRTU: onDataReceived() for read
ModbusRTU->>AppLogic: onRegisterChangeCallback(op, oldValue, newValue)
deactivate ModbusRTU
activate AppLogic
AppLogic->>AppLogic: if (op.address == SP_Address and state == WAITING_READ_VERIFY)
AppLogic->>AppLogic: if (newValue == pendingSP) -> SUCCESS!
AppLogic->>AppLogic: else -> FAILED!
AppLogic->>AppLogic: state = IDLE
deactivate AppLogic
Implementation Notes
- State Management: The component initiating the write (
OmronE5in this case) needs a simple state machine to track the verification process (e.g.,IDLE,WAITING_WRITE_ACK,WAITING_READ_VERIFY). - Callback Logic: The core logic is implemented in the
onWriteCallbackandonRegisterChangeCallbackhandlers. These handlers must inspect the incomingModbusOperationto ensure they are acting on the correct address for the correct slave. - Flattened Abstraction: This verification model works best with the "Flatten the Abstraction" approach, where the
OmronE5component interacts directly withModbusRTUand its callbacks, rather than going through theRTU_Baselayer.
7. Proposed New Class Design
Based on the goal of flattening the architecture, this new class design eliminates the RTU_Base, RegisterState, and Manager abstractions. PHApp becomes the central orchestrator connecting the Modbus services (ModbusRTU, ModbusTCP) to the various NetworkComponents that represent devices.
7.1. Class Diagram
classDiagram
class PHApp {
+ModbusRTU* modbusRTU
+ModbusTCP* modbusTCP
+OmronE5* omron_devices[]
+byId(ushort id) Component*
+setup()
+loop()
#onRegisterChange(op, oldValue, newValue)
}
class ModbusRTU {
-SlaveData _slaveData[]
+writeRegister(slaveId, address, value)
+readRegister(slaveId, address)
+getRegisterValue(slaveId, address, &value)
+setOnRegisterChangeCallback(callback)
+setOnWriteCallback(callback)
}
class ModbusTCP {
+registerModbus(component, info)
}
class NetworkComponent {
<<Abstract>>
#_networkValues: vector<NetworkValueBase*>
+virtual onRegisterUpdate(address, newValue)
+mb_tcp_write(reg, value)
+mb_tcp_read(reg)
}
class OmronE5 {
-NetworkValue m_pv
-NetworkValue m_sp
+setSP(uint16_t value)
+onRegisterUpdate(address, newValue) override
}
class NetworkValue {
-T m_value
+update(newValue)
+getValue() T
}
class SlaveData {
#coilMap[]
#registerMap[]
#entryPool[]
}
PHApp o-- "1" ModbusRTU : owns
PHApp o-- "1" ModbusTCP : owns
PHApp o-- "*" OmronE5 : owns device components
ModbusTCP ..> PHApp : Finds target component via byId() for writes
ModbusRTU ..> PHApp : Fires callbacks (e.g. onRegisterChange)
Component <|-- NetworkComponent
NetworkComponent <|-- OmronE5
NetworkComponent o-- "*" NetworkValue : manages
OmronE5 ..> ModbusRTU : Directly queues write operations
PHApp ..> OmronE5 : Routes callbacks via onRegisterUpdate()
ModbusRTU o-- "*" SlaveData : Manages RTU device cache
7.2. Key Changes in this Design
RTU_Baseis Eliminated:OmronE5now inherits directly fromNetworkComponent(which inherits fromComponent), removing the complex and RTU-specificRTU_Baseclass.RegisterStateis Eliminated: The state of a register is held in two places only: theModbusRTUcache (SlaveData) as the ground truth from the bus, and theNetworkValuewithin the specific component (OmronE5) for application logic. There is no third, intermediateRegisterStateobject.Manageris Eliminated: TheManagerclass, which was responsible for routing callbacks toRTU_Basedevices, is no longer needed.PHAppas the Router:PHApptakes on the role of the central router. It subscribes toModbusRTU's callbacks. When a register changes,PHAppreceives the callback, identifies which device component is affected (based on slave ID), and calls a method likeonRegisterUpdate()on that specific component instance.- Direct Command Path: When
OmronE5needs to write a value (e.g., in itssetSPmethod), it now callsmodbusRTU->writeRegister()directly, rather than manipulating an internalRegisterStateand waiting for a sync loop.
This new architecture is much cleaner, reduces memory overhead, and aligns with the data flow diagrams. It makes the system more performant and easier to reason about.