Pos3Analog
Path: src/Pos3Analog.h
Revision History: Initial documentation
The Pos3Analog component provides functionality for a 3-position analog switch interface, supporting both local (hardware) and remote (Modbus) control. It reads the state of a physical switch through analog inputs and exposes the switch state via Modbus. The component can be configured to operate in local mode (reading physical inputs) or remote mode (controlled via Modbus).
REQUIREMENTS
-
Hardware:
- Two analog input pins (upPin and downPin)
- ESP-32 microcontroller
-
Software:
- Platform.io build environment
- C++17 compatible compiler
FEATURES
- Reads a 3-position switch (UP, MIDDLE, DOWN) using two analog inputs
- Supports two control modes: LOCAL (hardware) and REMOTE (Modbus)
- Provides Modbus register interface for reading the current position
- Allows remote control of the switch position
- Configurable Modbus address for integration with industrial systems
- Debounced analog input reading with configurable interval
DEPENDENCIES
- ArduinoLog - For logging functionality
- Component - Base component class
- xmath - For range checking and math utilities
- ModbusTCP - For Modbus communication
- config.h - For configuration constants
- config-modbus.h - For Modbus-specific configurations
- enums.h - For enumerations used by the component
graph TD
Pos3Analog --> Component
Pos3Analog --> xmath
Pos3Analog --> ModbusTCP
Pos3Analog --> ArduinoLog
Component --> ArduinoLog
BEHAVIOUR
stateDiagram-v2
[*] --> Setup
Setup --> Idle
Idle --> ReadLocal: If ControlMode==LOCAL
Idle --> ReadRemote: If ControlMode==REMOTE
ReadLocal --> UpdateState: If position changed
ReadRemote --> UpdateState: If position changed
UpdateState --> NotifyChange
NotifyChange --> Idle
Idle --> ProcessModbus: ModbusRequest
ProcessModbus --> ChangeMode: Write to Mode Register
ProcessModbus --> ChangeRemoteValue: Write to RemoteValue Register
ProcessModbus --> ReturnCurrentValue: Read from Value Register
ChangeMode --> Idle
ChangeRemoteValue --> UpdateState: If Remote Mode & value changed
ReturnCurrentValue --> Idle
TODOS
PERFORMANCE
- Consider implementing hysteresis for analog readings to prevent flickering between states
- Optimize the loop interval for different application scenarios to balance responsiveness and CPU usage
SECURITY
- Add bounds checking on Modbus register access to prevent potential overflows
- Consider adding a validation mechanism for state changes to prevent rapid oscillations
COMPLIANCE
- Ensure compliance with industrial Modbus protocol standards for wider compatibility
- Document conformance to RS-485 electrical standards if used in that context
RECOMMENDATIONS
- Use pull-up/pull-down resistors on the analog input pins for more reliable readings
- Configure appropriate thresholds in config.h for the specific analog sensors being used
- Implement error handling for the case of both UP and DOWN inputs being active
- Consider adding a debounce mechanism for the switch position to prevent oscillation
EXAMPLE
This example demonstrates how to initialize and add a Pos3Analog component to your application:
#ifdef PIN_POS3_ANALOG_0_UP
pos3Analog_0 = new Pos3Analog(
this, // owner
PIN_POS3_ANALOG_0_UP, // upPin
PIN_POS3_ANALOG_0_DOWN,// downPin
ID_POS3_ANALOG_0, // id
POS3_ANALOG_0_MB_ADDR // modbusAddress
);
if (pos3Analog_0)
{
components.push_back(pos3Analog_0);
Log.infoln(F("Pos3Analog_0 initialized. UpPin:%d, DownPin:%d, ID:%d, MB:%d"),
PIN_POS3_ANALOG_0_UP, PIN_POS3_ANALOG_0_DOWN,
ID_POS3_ANALOG_0, POS3_ANALOG_0_MB_ADDR);
}
else
{
Log.errorln(F("Pos3Analog_0 initialization failed."));
}
#endif