machines/vendor/ski780/RS485-780.md
2025-01-31 11:56:13 +01:00

4.9 KiB
Raw Permalink Blame History

Extracted Tables

Functional Code Data Communication Address

Function Group Example Address Description
P0-16 F010H F0H (P0 group) + 10H (serial no. 16)
AC-08 AC08H ACH (AC group) + 08H (serial no. 8)
P0-16 No EEPROM 0010H 00H (No EEPROM) + 10H (serial no. 16)
P0-16 EEPROM F010H F0H (EEPROM) + 10H (serial no. 16)
AC-08 No EEPROM 4C08H 4CH (No EEPROM) + 08H (serial no. 8)
AC-08 EEPROM AC08H ACH (EEPROM) + 08H (serial no. 8)
PF 0xF000 - 0xFEFF Communication address
A0-AC 0xA000 - 0xACFF Communication address
U0 0x7000 - 0x70FF Communication address (read-only)

Parameter Address

Function Group Address Description
P-Group 030C Example for function code P3-12
A-Group 4005 Example for function code A0-05

Status Data

Command Address Status Function
3000H 1: forward running
2: reverse running
3: stop

Digital Output Terminal Control

Command Address Command Content
2001H BIT0: DO1 output control
BIT1: DO2 output control
BIT2: relay1 output control
BIT3: relay2 output control
BIT4: FMR output control
BIT5: VDO1
BIT6: VDO2
BIT7: VDO3
BIT8: VDO4
BIT9: VDO5

Analog Output Control

Command Address Command Content
2002H 0 7FFF means 0% - 100%
2003H 0 7FFF means 0% - 100%
2004H 0 7FFF means 0% - 100%

Fault Description of Frequency Converter

Fault Address Fault Information
8000H 0000: no fault
0001: reserve
0002: overcurrent
0003: overcurrent during deceleration
0004: overcurrent during constant speed

Modbus Communication Parameters

Parameter Address Parameter Description Data Range
1000H Communication setting -10000 10000
1010H PID set
1001H Running frequency
1011H PID feedback

Extracted Notes on Modbus

  1. SKI780 series frequency converter provides RS485 communication interface and supports Modbus-RTU slave communication protocol. Users can realize centralized control through computer or PLC, set the running command of the frequency converter, modify or read function code parameters, and read working state and fault information .

  2. Communication data structure details:

    • Idle slave with a transmission time of more than 3.5 bytes.
    • Slave address (ADR): Range 1-247; 0 is broadcast address.
    • Command codes:
      • 03: read slave parameter
      • 06: write slave parameter .
  3. The Modbus protocol for SKI780 inverter only supports the reading or writing of Word parameters, not bytes or bits. The read operation command is 0x03 and the write operation command is 0x06 .

  4. Communication setting values, such as the baud rate, data format, and local address, must match between the upper computer and the frequency converter for successful communication. The baud rate range includes 300 BPS to 115200 BPS .

  5. CRC verification mode uses the RTU frame format where CRC values are checked to ensure data integrity. CRC (Cyclical Redundancy Check) is applied to all 8-bit bytes in the message, excluding start, stop, and parity bits .

By structuring the documentation in this way, the relevant technical details are clear and accessible for anyone needing to implement or maintain the Modbus communication protocol with SKI780 series frequency converters.